Skip to main content

Table 3 Functions of smart devices controlled by remote management system (RMS)

From: A remote management system for control and surveillance of echinococcosis: design and implementation based on internet of things

Date Total number of collars Automatic delivering PZQ rate (%) Collar positioning rate (%) Deliver PZQ reminding rate (%) Fault reportrate (%) Location upload rate (%)
2019.09 20 20/20 (100.0) 56/60(93.3)b 20/20 (100.0) 5/6 (83.3) 20/20 (100.0)
2019.10 156 72/78 (92.3)a 1478/1560 (94.7)b 73/78 (93.6) 59/67 (88.1) 144/156 (92.3)
2019.11 264 119/132 (90.2)a 2468/2640 (93.5)b 123/132 (93.2) 121/137 (88.3) 242/264 (91.7)
2019.12 523 285/303 (94.1)a 3432/3676 (93.4)c 289/303 (95.4) 245/309 (79.3) 477/523 (91.2)
2020.01 523 479/523 (91.6)a 1895/2092 (90.6)d 491/523 (93.9) 242/284 (85.2) 462/523 (88.3)
2020.02 523 476/523 (91.0) 1869/2092 (89.3)d 471/523 (90.1) 278/328 (84.8) 583/523 (92.4)
2020.03 523 463/523 (88.5) 2382/2615 (90.7)d 469/523 (89.7) 337/388 (86.9) 488/523 (93.3)
Total 1914/2102 (91.1) 13 580/14 745 (92.1) 1936/2102 (92.1) 1287/1519 (84.7) 496/523 (94.8)
  1. aThere were 78, 132, 220 smart collars with no deworming time configured, so the PZQ bait was not delivered in September, October and November, respectively; b“once every 3 days” was set as position feedback cycle for each smart collar; c“once every 3 days” set as position feedback cycle for 264 smart collars and “once every 7 days” for 259 smart collars; d“once every 7 days” was set as position feedback cycle for each smart collar