Skip to main content

Table 2 Performance of PURE-LAMP, RDT and microscopy against nested PCR as reference

From: Performance of the procedure for ultra-rapid extraction and loop-mediated isothermal amplification (PURE-LAMP) method to detect malaria in Haiti

 

Sensitivity, n/d % (95% CI)

Specificity, n/d % (95% CI)

PPV, n/d % (95% CI)

NPV, n/d % (95% CI)

Kappa

PURE-LAMP Pan

89/89

100 (95.9–100)

976/985

99.1 (98.3–99.6)

89/98

90.8 (83.3–95.7)

976/976

100 (99.6–100)

0.95

PURE-LAMP Pf

88/89

98.9 (93.9–100)

977/985

99.2 (98.4–99.6)

88/96

91.7 (84.2–96.3)

977/978

99.9 (99.4–100)

0.95

RDT Pan

54/89

60.7 (49.7–70.9)

983/985

99.8 (99.3–100)

54/56

96.4 (87.7–99.6)

983/1018

96.6 (95.2–97.6)

0.73

RDT Pf

76/89

85.4 (76.3–92.0)

980/985

99.5 (98.8–99.8)

76/81

93.8 (86.2–98.0)

980/993

98.7 (97.8–99.3)

0.88

Microscopy

44/89

49.4 (38.7–60.2)

978/985

99.3 (98.5–99.7)

44/51

86.3 (73.7–94.3)

978/1023

95.6 (94.1–96.8)

0.60

  1. NPV Negative predictive value, PPV Positive predictive value, PURE-LAMP procedure for ultra-rapid extraction–loop-mediated isothermal amplification, Pan tubes for diagnosis of Plasmodium genus, Pf P. falciparum-specific tubes, RDT Pan rapid diagnostic test band to detect Plasmodium lactodehydrogenase, RDT Pf band for detection of P. falciparum-specific histidine rich protein II, n/d numerator/denominator