- Research Article
- Open access
- Published:
Detection of Schistosoma mansoni DNA using polymerase chain reaction from serum and dried blood spot card samples of an adult population in North-western Tanzania
Infectious Diseases of Poverty volume 10, Article number: 15 (2021)
Abstract
Background
Real-time polymerase chain reaction (PCR) is a sensitive and specific method for diagnosing schistosomiasis. However, this method should be performed in a laboratory, usually located distant from the sample collection site. Therefore, it is important to have fast sampling preservation methods, which allow simple transport prior to DNA extraction and amplification. The aim of this study was to verify if blood samples applied to filter paper are suitable for analysis of Schistosoma mansoni DNA by real-time PCR.
Methods
A cross-sectional study was conducted among 100 study participants aged 17 to 70Â years in a fishing village on the southern shore of Lake Victoria, Tanzania. Serum samples and ethylenediaminetetraacetic acid (EDTA)-anticoagulated whole blood for preparation of dried blood spots (DBS) were collected to test for Schistosoma mansoni infection by real-time PCR. A combined diagnostic reference of positive results of serum-based real-time PCR and the Kato-Katz (KK) method was used for analysis. Sensitivity and negative predictive value (NPV) were calculated. The Wilcoxon signed-rank test was chosen to compare the mean cycle threshold (Ct) values from serum and DBS.
Results
According to the reference, 92.5% S. mansoni positive samples were determined. The serum-based real-time PCR performed excellently with 95.4% sensitivity, whereas the DBS-based real-time PCR showed a low sensitivity (45.4%). The Ct-values were significantly higher in DBS (median: 37.3) than in serum samples (median: 27.5, P < 0.001), reflecting a lower parasite-specific DNA load on the filter cards. With increasing egg counts, an increase in sensitivity was observed for all methods. The POC-CCA test and the serum-based real-time PCR showed a sensitivity of 100% for medium and severe infections. The DBS real-time PCR showed a sensitivity of only 85.7% even for severe infections.
Conclusions
DBS-based real-time PCR did not provide good results in our study and therefore should not be recommended or must be tested concerning temperature of storage, storage duration, use of different filter papers and extraction methods before it is used in future studies. In contrast, our results showed that the POC-CCA test is a sensitive and precise test for detecting S. mansoni infections .
Background
Schistosomiasis is a major neglected tropical disease which leads to significant economic and public health consequences, particularly in rural communities [1, 2]. The disease is caused by trematodes of the genus Schistosoma [3]. In sub-Saharan Africa, the main burden of the disease is caused by two human schistosome species, Schistosoma mansoni and S. haematobium [4]. In endemic countries mass drug administration (MDA) campaigns with praziquantel (PZQ) have been often performed to reduce the morbidity [5]. This has led to lower infection intensities despite high parasite transmission rates. In these situations, but also under low prevalence and post-treatment conditions, highly sensitive and specific diagnostic tests are necessary [6, 7]. The most commonly used diagnostic methods for the detection of S. mansoni, the Kato-Katz thick smears technique (KK) for the microscopic identification of eggs in faeces and the rapid diagnostic test for the detection of circulating cathodic antigen (POC-CCA), lack sensitivity particularly in low intensity infections[8]. Due to the diagnostic accuracy, and the higher sensitivity, including the ability to detect early pre-patent infections, polymerase chain reaction (PCR)-based methods for detection of parasite DNA have moved into the focus of research [8,9,10,11]. Numerous studies have shown that different types of samples, such as blood [9, 12, 13], urine [14,15,16], stool [9, 17], infective snail tissue [18, 19] and cercaria in contaminated water [20], are suitable for the detection of schistosome DNA with molecular techniques. In the reviews of Weerakoon et al. [8, 21] all the different diagnostic methods were presented in great detail. Considering that the result of molecular diagnostic methods depends directly on the quantity and quality of the DNA used, the type of sample, sample conservation, sample storage as well as DNA extraction from these samples play a central role [16, 22,23,24]. The samples usually have to be transported to a central laboratory for processing and cannot be examined directly in the field [8]. Depending on the nature of the sample, this may require feasible and rapid preservation of the DNA, for example stabilisation of DNA in urine with special urine preservation reagents [25], freezing serum [26] or preserving DNA on dried blood spots (DBS) [27]. The use of DBS has the advantage that no cold chain is required for the transport and storage of the samples [28]. In addition, no venipuncture is required for the preparation, only blood from the fingertip [29].
The objective of this study was to test the usefulness of dried blood on DBS in comparison to frozen serum samples for molecular detection of S. mansoni DNA using real-time PCR in diagnosing cases of schistosomiasis due to S. mansoni in a high-prevalence area.
Materials and methods
Study area and population
A cross-sectional study was conducted in March 2018 in the community of Kayenze, a fishing village in Ilemela district on the southern shore of Lake Victoria in north-western Tanzania. The majority of the inhabitants depend on the lake for domestic and economic activities including fishing, farming, washing, bathing, cooking, drinking and recreation. The region is endemic for S. mansoni [30,31,32] and the high occupational exposure keeps the intensity of S. mansoni infection high in adulthood [33]. In the study by Mazigo et al. a prevalence of 54.2% and a mean value of 202 eggs per gram stool (EPG) was found in the same region [30, 31]. Annual MDA using praziquantel and albendazole against helminth infections in this village is school-based, targets school children and not adults [30]. The study included only participants between the ages of 17 and 70Â years who provided written informed consent.
Collection and preparation of blood samples
One hundred participants were assessed for infection with S. mansoni. Serum samples were obtained after centrifugation of coagulated blood samples at 1200×g for 5 min. The supernatant was centrifuged for a further 15 min at 3000×g. Both centrifugation steps were performed at ambient temperature. The resulting supernatant was pipetted into 2 ml tubes and stored and transported in special thermal packaging at − 20 °C. Dried blood spots were prepared by dropping 125 µl ethylenediaminetetraacetic acid (EDTA)-anticoagulated whole blood onto Whatman™ FTA™ Classic Cards (GE Healthcare Life Sciences, Piscataway, NJ, USA). Cards were dried away from direct sunlight, placed into individual zip bags with desiccant three hours after preparation, and stored at room temperature until processing [34, 35].
Microscopic examination
Stool samples were evaluated for the presence of S. mansoni eggs by using the quantitative KK thick smear technique. For the KK method two thick smears were prepared from different parts of a single stool sample using a template of 41.7Â mg (Vestergaard Frandsen, Lausanne, Switzerland), following a standard protocol [36, 37]. After 24Â h, the smears were independently examined for S. mansoni eggs by two experienced laboratory technicians of the National Institute for Medical Research (NIMR) laboratory. For quality assurance, 10% of the negative and positive KK thick smears were re-examined by a third laboratory technician.
Point-of-care circulating cathodic antigen (POC-CCA) urine rapid diagnostic test
Urine samples were tested for circulating cathodic antigen (CCA) of Schistosoma by the POC-CCA cassette test according to the protocol described by the manufacturer and noted as positive or negative (Rapid Diagnostics, Pretoria, South Africa). Trace readings were considered as positive test results.
DNA extraction from serum samples
DNA extractions from 2 ml serum were performed using the QIAamp Circulating Nucleic Acid Kit according to the manufacturer’s suggestions (Qiagen, Hilden, Germany). DNA was stored at -20 °C after extraction.
DNA extraction from dried blood spot cards
DNA extraction from the DBS was performed approximately 4 months after sample collection. Harris Uni-Core puncher (Qiagen, Hilden, Germany) was used to punch out circles (6 mm in diameter) of the DBS. Between samples, the Harris Uni-Core was cleaned as described previously [38]. Eight paper discs from each sample were punched out and distributed to four 1.5 ml Eppendorf tubes containing 200 μl PBS each. Tubes were placed on a rotator at room temperature overnight (16–18 h, 300 rpm). The entire PBS solution from the four tubes of the same sample was transferred to one Qiagen QIAmp 2 ml column tube. DNA was precipitated and concentrated using the QIAmp DNA Blood Mini Kit (Qiagen, MD) according to the manufacturer's protocol.
Amplification by real-time PCR
Detection of cell-free S. mansoni DNA samples was performed according to a previously published protocol [39] using a set of primers and probes complementary to a 121 bp tandem repeat sequence of S. mansoni strain SM 1–7 (GenBank accession number: M61098) described by Hamburger et al. [40]. Primer sequences were: Sm FW 5′-CCG ACC AAC CGT TCT ATG A-3′; Sm RV 5′-CAC GC TCT CG C AAA TAA TCT AAA-3′; Sm probe 5′-[FAM] TCG TTG TAT CTC CGA AAC CAC TGG ACG [(BHQ1])-3′ all synthesized by Eurofins Genomics, Ebersberg, Germany.
The 25 µl reaction mix contained 2.5 µl DNA, 1 × QuantiFast Pathogen Master Mix (QuantiFast ® Pathogen PCR + IC Kit, Qiagen, Hilden, Germany), 400 nmol/L of each Sm Primer and 200 nmol/L of Sm probe. The PCR runs consisted of an initial step of 5 min at 95 °C followed by 40 successive cycles of 15 s at 95 °C and 30 s at 60 °C. The reaction was run on the StepOne real-time PCR system (Applied Biosystems). DNA detection was expressed by cycle threshold (Ct)-values. In every run, the non-template control was negative (Ct = 0), the positive control (S. mansoni egg DNA) was positive (Ct < 22) and the internal control to test successful amplification and to exclude the presence of PCR inhibitors was positive (Ct < 33). A test was considered positive when the threshold was attained within 40 PCR cycles (Ct < 40). Each sample was tested only once, not in replicates.
Statistical analyses
Statistical analysis were carried out using IBM SPSS Statistics version 24 (SPSS Inc., Chicago, USA) and Microsoft Excel 2013 (Microsoft Corporation, Redmond, USA). A P-value lower than 0.05 was considered statistically significant.
The prevalence of S. mansoni was determined for each diagnostic method. The arithmetic mean egg count was calculated as the average egg count of the two KK smears, and classes of intensity of S. mansoni were determined as light (1–99 EPG), moderate (100–399 EPG) and heavy (> 400 EPG). The thresholds are set according to the values published by the WHO [41]. Medians were calculated for the Ct-values. This study used a combined diagnostic reference of positive results by serum-based real-time PCR and positive egg counts as determined by KK. A combined reference is used to obtain a reliable result and has been described in other studies [42, 43]. Since this approach assumes a specificity of 100% for both test methods, only sensitivity and negative predicted value (NPV) were calculated for the assays used. Diagnostic results were converted to binary variables (1 = positive and 0 = negative). Kappa coefficient (κ) was used to statistically estimate the agreement between one diagnostic tool compared to the reference. Differences in the positivity rate between our reference and the other used methods to diagnose schistosomiasis were determined using the McNemar test.
By using the real-time PCR method, the Ct-value is detected. The Ct is defined as the number of cycles required for the fluorescent signal to cross the threshold (i.e. exceeds background level). Ct levels are inversely proportional to the amount of target nucleic acid in the sample (the lower the Ct level the greater the amount of target nucleic acid in the sample). A nonparametric test (Wilcoxon signed-rank test) was used to compare the median Ct-values of the two different methods.
Results
Demographic information of participants
Study participants who provided sample material for the current study consisted of 76 females and 24 males with a mean age of 35.6Â years (range: 17 to 70Â years). Of the 100 study participants, two did not provide stool samples and five participants did not provide blood for serum collection. Specimens from 93 individuals were investigated by all methods.
Prevalence of Schistosoma mansoni using KK technique and POC-CCA test
Microscopic stool examination by KK method showed eggs of S. mansoni in 43.9% of the samples. Egg loads varied between 12 and 1248 EPG with a median of 36 EPG. The prevalence determined with the commercially available POC-CCA rapid test was 80%.
Prevalence of Schistosoma mansoni based on DNA detection using PCR
Real-time PCR detected S. mansoni DNA in 88.4% of the serum samples with Ct-values ranging between 22.6 and 37.4 and a median Ct-value of 30.1. In DBS, real-time PCR yielded 41% S. mansoni positive samples with Ct values between 32.5 and 39.9 and a median Ct-value of 37.2 (Table 1). Comparing the 37 samples, which were positive by serum-based and DBS-based real-time PCR, showed that the Ct values were significantly higher in the DBS (median: 37.3, minimum: 32.5, maximum: 39.9) than in the serum samples (median: 27.5, minimum: 22.6, maximum: 33.6) of the same study participants (P < 0.001) (Fig. 1).
A combination of the parasitological KK test and real-time PCR of serum samples was used as reference. According to this procedure, 92.5% (86/93) S. mansoni positive samples were determined. Serum-based real-time PCR displayed the highest sensitivity (95.4%) and NPV (63.6%), as well as high Kappa agreement (k = 0.755, P < 0.001). This technique missed 4 out of 86 positive cases. The lowest sensitivity (45.4%) and NPV (13%) was achieved by the method of DBS-based real-time PCR. The positivity rate obtained from the combination of KK and serum-based real-time PCR was statistically higher than that obtained from microscopy (P < 0.001), the POC-CCA test (P = 0.002) or DBS-based real-time PCR (P < 0.001). In addition, there was a poor agreement among KK or DBS real-time PCR and the reference. These results are summarized in Table 2.
Of the 42 KK-positive participants, of whom complete sample sets were available, 29 (69%) showed light, 6 (14.3%) moderate and 7 (16.7%) heavy S. mansoni infection intensities. When comparing the sensitivities of the individual test methods with regard to the different infection intensities, it was shown that the sensitivity of all methods increased with increasing egg counts. Both the POC-CCA test and the serum-based real-time PCR showed a sensitivity of 100% for medium and severe infections. The DBS real-time PCR showed a sensitivity of only 85.7% even for severe infections (Table 3). Of the 56 KK-negative samples, 37 were positive (66.1%) using the POC-CCA test and 12 were positive (21.4%) using the DBS-PCR. Serum PCR detected 45 of 52 (86.5%) KK-negative samples as positive.
Discussion
Numerous studies in recent years have shown that PCR-based techniques are highly specific and sensitive for the diagnosis of schistosomiasis. However, these assays are rarely used in Schistosoma endemic countries, as it requires expensive equipment and highly skilled laboratory personnel [44]. In addition, in remote tropical areas, sampling, transport and storage of venous blood samples are often sub-optimal [29]. In our study, we investigated the value of detecting cell-free S. mansoni DNA in serum and DBS as an alternative sample source compared to the classical diagnostic methods for the detection of eggs in stool or the detection of schistosome antigens in urine. Most infections with S. mansoni were detected by serum-based real-time PCR (88.4%), followed by the POC-CCA test (80.0%). Comparatively few infections were identified using the DBS-based real-time PCR method (41.0%) and the microscopic KK method (43.9%). In the study by EspÃrito-Santo et al. in a low endemic setting, it was also shown that the positivity rate of serum-based real-time PCR was higher than that obtained using parasitological tests [45]. To determine diagnostic accuracy, the combined results of microscopy and serum-based real-time PCR were used as a reference in this study, with both methods considered 100% specific. This procedure has also been reviewed and applied in other studies [42, 46]. The serum-based real-time PCR showed excellent performance with a sensitivity of 95.4%, while DBS-based real-time PCR showed the lowest sensitivity (45.4%). The sensitivity of the serum-based real-time PCR was also higher than that of the POC-CCA test (95.4% vs 84.9%) when considering the total collective.
According to WHO guidelines, S. mansoni infection intensities can be classified on the basis of KK results [41]. The majority of the KK-positive study participants (69.0%) showed light infection intensities. In this study the highest sensitivity was found for the POC-CCA method (96.6%) followed by serum-based real-time PCR (89.3%). Thus, despite the microscopic findings of eggs, no S. mansoni infection could be detected in some serum samples with real-time PCR. Possibly the samples were mixed up or incorrectly labelled, and urine and blood samples were not taken from the same participant. However, false negative results of PCR methods have been reported by different research groups [47, 48]. One possible cause could be degradation of DNA during transport from the field or during storage of the samples [49].
Observation of the Ct-values showed that these were significantly higher in DBS (median: 37.3) than in serum samples (median: 27.5, P < 0.001), which reflects a lower parasite-specific DNA load on the filter cards. This discrepancy could be due to the small amount of blood applied to the DBSs and the small volume used for the extraction process, which might lead to a higher rate of false negative results. A 6 mm diameter punch contains approximately 8.7 ± 1.9 μl of spotted blood, so it can be assumed that the concentration of genetic material is low [29]. To increase the volume of the analyzed blood eight punches were used in this study. Nevertheless, DBS-based real-time PCR did not perform well in our study. Similar results have also been observed in various malaria studies. In Tanzania, Strøm et al. found almost two times more positive results when a protocol with 200 μl venous blood was used: The positivity of the PCR was 24.5% when using 200 μl whole blood and 11.2% when using DBS [50]. The study by Canier et al. comparing malaria PCR detection from DBS and venous blood samples showed no significant difference in the detection rates of malaria parasites. False-negative results were obtained when using DBS, but these were Plasmodium vivax infections, which are often found in asymptomatic individuals with very low parasite density [51]. Possibly the sensitivity of this method could be increased by using other extraction methods or two sequential amplifications by PCR. Promising results have already been obtained by EspÃrito-Santo et al. on the detection of S. mansoni in stool samples by PCR [52]. In addition, the data from several studies suggest that there may be differences between filter papers from different manufacturers and that further studies should be carried out to evaluate several types of filter paper [53,54,55].
DBS cards have been used in numerous studies over the last five decades and have proven to be a simple and well-accepted sampling tool [55]. The collection of DBS is simple, as only a finger prick is required and no venipuncture [28, 29]. Furthermore, DBS require simpler storage and transport conditions, do not need a cold chain, and allow retrospective PCR analysis [28, 56]. Nevertheless, DBS did not demonstrate to be a valuable alternative sample source in the present study and could not simplify the applicability of DNA-based diagnosis of schistosomiasis in the field.
This study was not carried out without limitations. Given the lack of a diagnostic standard, two test methods were combined in the current work to form an artificial reference. As this implied that the tests were evaluated to a certain extent on the basis of their own results, only a limited interpretation of the data is possible. Also, it is known that degradation of DNA in DBS can occur during storage and extraction and affects the sensitivity of diagnostic assays [56,57,58,59]. Therefore, further studies with different storage conditions (humidity and temperature), storage duration and different types of filter paper should be performed to determine in which way this affects the results of DBS-based real-time PCR.
Conclusions
The results of the DBS-based real-time PCR in our study do not suggest the use of DBS cards as an alternative sample source for the diagnosis of S. mansoni. Extensive testing must be done before filter cards are used in future studies to detect circulating DNA from Schistosoma by real-time PCR. In addition, our results showed that the POC-CCA test is a valuable, easy to use and accurate test for detecting S. mansoni infections in moderate or highly endemic areas. There were only minor differences compared to the serum-based real-time PCR. Even in areas with low prevalence and intensity, the prevalence determined by POC-CCA is higher than that of KK and provides a sensitive and accurate screening tool for S. mansoni.
Availability of data and materials
All relevant data are within the paper and its Supporting Information files.
Abbreviations
- CCA:
-
Circulating cathodic antigen
- CI :
-
Confidence intervals
- Ct:
-
Cycle threshold
- DBS:
-
Dried blood spot
- EDTA:
-
Ethylenediaminetetraacetic acid
- EPG:
-
Eggs per gram
- KK:
-
Kato-Katz
- MDA:
-
Mass drug administration
- NIMR:
-
National Institute for Medical Research
- NPV:
-
Negative predicted value
- PBS:
-
Phosphate-buffered saline
- PCR:
-
Polymerase chain reaction
- POC-CCA:
-
Point-of-care circulating cathodic antigen
- PZQ:
-
Praziquantel
- WASH:
-
Water, sanitation and hygiene
- WHO:
-
World Health Organization
References
He P, Song L, Xie H, Liang J, Yuan D, Wu Z, et al. Nucleic acid detection in the diagnosis and prevention of schistosomiasis. Infect Dis Poverty. 2016;5:25.
Colley DG, Bustinduy AL, Secor WE, King CH. Human schistosomiasis. Lancet Lond Engl. 2014;383:2253–64.
Clerinx J, Bottieau E, Wichmann D, Tannich E, Van Esbroeck M. Acute schistosomiasis in a cluster of travelers from Rwanda: diagnostic contribution of schistosome DNA detection in serum compared to parasitology and serology. J Travel Med. 2011;18:367–72.
Utzinger J, Raso G, Brooker S, De Savigny D, Tanner M, Ørnbjerg N, et al. Schistosomiasis and neglected tropical diseases: towards integrated and sustainable control and a word of caution. Parasitology. 2009;136:1859.
Colley DG. Morbidity control of schistosomiasis by mass drug administration: how can we do it best and what will it take to move on to elimination? Trop Med Health. 2014;42(2 Suppl):25–32.
Kato-Hayashi N, Leonardo LR, Arevalo NL, Tagum MaNB, Apin J, Agsolid LM, et al. Detection of active schistosome infection by cell-free circulating DNA of Schistosoma japonicum in highly endemic areas in Sorsogon Province, the Philippines. Acta Trop. 2015;141:178–83.
Cavalcanti MG, Silva LF, Peralta RHS, Barreto MGM, Peralta JM. Schistosomiasis in areas of low endemicity: a new era in diagnosis. Trends Parasitol. 2013;29:75–82.
Weerakoon KG, Gordon CA, McManus DP. DNA diagnostics for schistosomiasis control. Trop Med Infect Dis. 2018;3:81.
Pontes LA, Dias-Neto E, Rabello A. Detection by polymerase chain reaction of Schistosoma mansoni DNA in human serum and feces. Am J Trop Med Hyg. 2002;66:157–62.
Bergquist R, Gray DJ. Schistosomiasis elimination: beginning of the end or a continued march on a trodden path. Trop Med Infect Dis. 2019;4:76.
Fernández-Soto P, Gandasegui J, RodrÃguez CC, Pérez-Arellano JL, Crego-Vicente B, Diego JG-B, et al. Detection of Schistosoma mansoni-derived DNA in human urine samples by loop-mediated isothermal amplification (LAMP). PLoS One. 2019;14:e0214125.
Cnops L, Soentjens P, Clerinx J, Esbroeck MV. A Schistosoma haematobium -specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants. PLoS Negl Trop Dis. 2013;7:e2413.
Xia CM, Rong R, Lu ZX, Shi CJ, Xu J, Zhang HQ, et al. Schistosoma japonicum: A PCR assay for the early detection and evaluation of treatment in a rabbit model. Exp Parasitol. 2009;121:175–9.
Lodh N, Naples JM, Bosompem KM, Quartey J, Shiff CJ. Detection of parasite-specific DNA in urine sediment obtained by filtration differentiates between single and mixed infections of Schistosoma mansoni and S. haematobium from endemic areas in Ghana. PLoS One. 2014;9:e91144.
Lodh N, Mwansa JCL, Mutengo MM, Shiff CJ. Diagnosis of Schistosoma mansoni without the stool: comparison of three diagnostic tests to detect Schistosoma mansoni infection from filtered urine in Zambia. Am J Trop Med Hyg. 2013;89:46–50.
Ibironke OA, Phillips AE, Garba A, Lamine SM, Shiff C. Diagnosis of Schistosoma haematobium by detection of specific DNA fragments from filtered urine samples. Am J Trop Med Hyg. 2011;84:998–1001.
Fuss A, Mazigo HD, Tappe D, Kasang C, Mueller A. Comparison of sensitivity and specificity of three diagnostic tests to detect Schistosoma mansoni infections in school children in Mwanza region, Tanzania. PLoS One. 2018;13:e0202499.Â
Abbasi I, King CH, Muchiri EM, Hamburger J. Detection of Schistosoma mansoni and Schistosoma haematobium DNA by loop-mediated isothermal amplification: identification of infected snails from early prepatency. Am J Trop Med Hyg. 2010;83:427–32.
Allan F, Dunn AM, Emery AM, Stothard JR, Johnston DA, Kane RA, et al. Use of sentinel snails for the detection of Schistosoma haematobium transmission on Zanzibar and observations on transmission patterns. Acta Trop. 2013;128:234–40.
Hertel J, Kedves K, Hassan AHM, Haberl B, Haas W. Detection of Schistosoma mansoni cercariae in plankton samples by PCR. Acta Trop. 2004;91:43–6.
Weerakoon KG, McManus DP. Cell-free DNA as a diagnostic tool for human parasitic infections. Trends Parasitol. 2016;32:378–91.
Smit PW, Elliott I, Peeling RW, Mabey D, Newton PN. An overview of the clinical use of filter paper in the diagnosis of tropical diseases. Am J Trop Med Hyg. 2014;90:195–210.
Fernández-Soto P, Tirado VV, RodrÃguez CC, Pérez-Arellano JL, Muro A. Long-term frozen storage of urine samples: A trouble to get PCR results in Schistosoma spp. DNA detection? PLoS One. 2013;8:e61703.
Sarhan RM, Kamel HH, Saad GA, Ahmed OA. Evaluation of three extraction methods for molecular detection of Schistosoma mansoni infection in human urine and serum samples. J Parasit Dis Off Organ Indian Soc Parasitol. 2015;39:499–507.
Lin SY, Linehan JA, Wilson TG, Hoon DSB. Emerging utility of urinary cell-free nucleic acid biomarkers for prostate, bladder, and renal cancers. Eur Urol Focus. 2017;3:265–72.
Cnops L, Tannich E, Polman K, Clerinx J, Van Esbroeck M. Schistosoma real-time PCR as diagnostic tool for international travellers and migrants. Trop Med Int Health. 2012;17:1208–16.
Tran TM, Aghili A, Li S, Ongoiba A, Kayentao K, Doumbo S, et al. A nested real-time PCR assay for the quantification of Plasmodium falciparum DNA extracted from dried blood spots. Malar J. 2014;13:393.
Choi EH, Lee SK, Ihm C, Sohn YH. Rapid DNA extraction from dried blood spots on filter paper: potential applications in biobanking. Osong Public Health Res Perspect. 2014;5:351–7.
Kumar A, Mhatre S, Godbole S, Jha P, Dikshit R. Optimization of extraction of genomic DNA from archived dried blood spot (DBS): potential application in epidemiological research & bio banking. Gates Open Res. 2019;2:57.
Mazigo HD, Dunne DW, Wilson S, Kinung’hi SM, de Moira AP, Jones FM, et al. Co-infection with Schistosoma mansoni and human immunodeficiency virus-1 (HIV-1) among residents of fishing villages of north-western Tanzania. Parasit Vectors. 2014;7:587.Â
Mazigo HD, Dunne DW, Morona D, Lutufyo TE, Kinunghi SM, Kaatano G, et al. Periportal fibrosis, liver and spleen sizes among S. mansoni mono or co-infected individuals with human immunodeficiency virus-1 in fishing villages along Lake Victoria shores, North-Western, Tanzania. Parasit Vectors. 2015;8:260.
Malenganisho WLM, Magnussen P, Friis H, Siza J, Kaatano G, Temu M, et al. Schistosoma mansoni morbidity among adults in two villages along Lake Victoria shores in Mwanza District, Tanzania. Trans R Soc Trop Med Hyg. 2008;102:532–41.
Kardorff R, Gabone RM, Mugashe C, Obiga D, Ramarokoto CE, Mahlert C, et al. Schistosoma mansoni-related morbidity on Ukerewe Island, Tanzania: clinical, ultrasonographical and biochemical parameters. Trop Med Int Health TM IH. 1997;2:230–9.
Downs JA, Corstjens PLAM, Mngara J, Lutonja P, Isingo R, Urassa M, et al. Correlation of serum and dried blood spot results for quantitation of Schistosoma circulating anodic antigen: a proof of principle. Acta Trop. 2015;150:59–63.
Grüner N, Stambouli O, Ross RS. Dried blood spots—preparing and processing for use in immunoassays and in molecular techniques. J Vis Exp. 2015;(97):52619.
WHO | Basic laboratory methods in medical parasitology (archived). WHO. http://www.who.int/malaria/publications/atoz/9241544104_part1/en/. Accessed 28 Aug 2017.
Katz N, Chaves A, Pellegrino J. A simple device for quantitative stool thick-smear technique in Schistosomiasis mansoni. Rev Inst Med Trop Sao Paulo. 1972;14:397–400.
Strøm GE, Tellevik MG, Fataki M, Langeland N, Blomberg B. No asymptomatic malaria parasitaemia found among 108 young children at one health facility in Dar es Salaam, Tanzania. Malar J. 2013;12:417.
Wichmann D, Panning M, Quack T, Kramme S, Burchard G-D, Grevelding C, et al. Diagnosing schistosomiasis by detection of cell-free parasite DNA in human plasma. PLoS Negl Trop Dis. 2009;3:e422.
Hamburger J, Turetski T, Kapeller I, Deresiewicz R. Highly repeated short DNA sequences in the genome of Schistosoma mansoni recognized by a species-specific probe. Mol Biochem Parasitol. 1991;44:73–80.
WHO | Prevention and control of schistosomiasis and soil-transmitted helminthiasis: WHO Technical Report Series N° 912. WHO. http://www.who.int/intestinal_worms/resources/who_trs_912/en/. Accessed 28 Aug 2017.
Vinkeles Melchers NVS, van Dam GJ, Shaproski D, Kahama AI, Brienen EAT, Vennervald BJ, et al. Diagnostic performance of Schistosoma real-time PCR in urine samples from Kenyan children infected with Schistosoma haematobium: day-to-day variation and follow-up after praziquantel treatment. PLoS Negl Trop Dis. 2014;8:e2807.Â
van Dam GJ, Xu J, Bergquist R, de Dood CJ, Utzinger J, Qin Z-Q, et al. An ultra-sensitive assay targeting the circulating anodic antigen for the diagnosis of Schistosoma japonicum in a low-endemic area, People’s Republic of China. Acta Trop. 2015;141:190–7.
van Lieshout L, Roestenberg M. Clinical consequences of new diagnostic tools for intestinal parasites. Clin Microbiol Infect. 2015;21:520–8.
EspÃrito-Santo MCC, Alvarado-Mora MV, Dias-Neto E, Botelho-Lima LS, Moreira JP, Amorim M, et al. Evaluation of real-time PCR assay to detect Schistosoma mansoni infections in a low endemic setting. BMC Infect Dis. 2014;14:558.
Coulibaly JT, N’Gbesso YK, Knopp S, N’Guessan NA, Silué KD, van Dam GJ, et al. Accuracy of urine circulating cathodic antigen test for the diagnosis of Schistosoma mansoni in preschool-aged children before and after treatment. PLoS Negl Trop Dis. 2013;7:e2109.
Allam AF, Kader O, Zaki A, Youssef Shehab A, Farag HF. Assessing the marginal error in diagnosis and cure of Schistosoma mansoni in areas of low endemicity using Percoll and PCR techniques. Trop Med Int Health. 2009;14:316–21.
Pontes LA, Oliveira MC, Katz N, Dias-Neto E, Rabello A. Comparison of a polymerase chain reaction and the Kato-Katz technique for diagnosing infection with Schistosoma Mansoni. Am J Trop Med Hyg. 2003;68:652–6.
Jb V, Mk H. Biological sample collection, processing, storage and information management. IARC scientific publications. 2011. https://pubmed.ncbi.nlm.nih.gov/22997855/. Accessed 14 Oct 2020.
Ge S, Sabrina M, Maulidi F, Nina L, Bjørn B. PCR targeting Plasmodium mitochondrial genome of DNA extracted from dried blood on filter paper compared to whole blood. Malar J. 2014;13:137.
Canier L, Khim N, Kim S, Eam R, Khean C, Loch K, et al. Malaria PCR Detection in Cambodian low-transmission settings: dried blood spots versus venous blood samples. Am J Trop Med Hyg. 2015;92:573.
do EspÃrito-Santo MCC, Alvarado-Mora MV, Pinto PLS, Carrilho FJ, Pinho JRR, Gryschek RCB. Two sequential PCR amplifications for detection of Schistosoma mansoni in stool samples with low parasite load. Rev Inst Med Trop São Paulo. 2012;54:245–8.
Rottinghaus EK, Beard RS, Bile E, Modukanele M, Maruping M, Mine M, et al. Evaluation of dried blood spots collected on filter papers from three manufacturers stored at ambient temperature for application in HIV-1 drug resistance monitoring. PLoS One. 2014;9:e109060.
Chace DH, Hannon WH. Filter paper as a blood sample collection device for newborn screening. Clin Chem. 2016;62:423–5.
Lim MD. Dried blood spots for global health diagnostics and surveillance: opportunities and challenges. Am J Trop Med Hyg. 2018;99:256.
Strøm GEA, Tellevik MG, Hanevik K, Langeland N, Blomberg B. Comparison of four methods for extracting DNA from dried blood on filter paper for PCR targeting the mitochondrial Plasmodium genome. Trans R Soc Trop Med Hyg. 2014;108:488–94.
Färnert A, Arez AP, Correia AT, Björkman A, Snounou G, do Rosário V. Sampling and storage of blood and the detection of malaria parasites by polymerase chain reaction. Trans R Soc Trop Med Hyg. 1999;93:50–3.
Chaorattanakawee S, Natalang O, Hananantachai H, Nacher M, Brockman A, Krudsood S, et al. Storage duration and polymerase chain reaction detection of Plasmodium falciparum from blood spots on filter paper. Am J Trop Med Hyg. 2003;69:42–4.
Ghantous A, Saffery R, Cros M-P, Ponsonby A-L, Hirschfeld S, Kasten C, et al. Optimized DNA extraction from neonatal dried blood spots: application in methylome profiling. BMC Biotechnol. 2014;14:60.
Acknowledgements
We gratefully acknowledge the technicians of the National Institute for Medical Research, Mwanza, who were involved in sample collection and microscopic analysis. They also assisted in drug administration and helped with the collection of information and data necessary for this study. We would also like to thank the study participants for their cooperation.
Funding
This study was funded by the Georg Ludwig Rexroth Foundation (http://www.rexroth-stiftung.de) and German Academic Exchange Service (Deutscher Akademischer Austauschdienst, DAAD grant number 57141273 (https://www.daad.de/de/)). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Author information
Authors and Affiliations
Contributions
AF, AM conceived the experiment(s). AF conducted the experiment(s). AF and HDM analysed the results. AF wrote the draft manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Written informed consent was obtained from all participants. This project was reviewed and specifically approved by the Catholic University of Health and Allied Sciences (CUHAS), Ethics Review Board, Mwanza, Tanzania (Research Clearance Certificate No CREC/243/2017) and by the National Institute for Medical Research (Research Clearance Certificate No NIMR/HQ/R.8a/Vol.IX/2679). Participants who were positive by microscopic examination or POC-CCA test cassette for S. mansoni were treated with PZQ using the WHO recommended clinical dosage (40Â mg/kg body weight).
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Fuss, A., Mazigo, H.D. & Mueller, A. Detection of Schistosoma mansoni DNA using polymerase chain reaction from serum and dried blood spot card samples of an adult population in North-western Tanzania. Infect Dis Poverty 10, 15 (2021). https://doi.org/10.1186/s40249-021-00798-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s40249-021-00798-4